Water flowing freely through the vent of a Wilkins RK34-375V after freeze/thaw means the poppet assembly cracked from ice expansion and no longer seats. Good news: you don't need a whole new unit.
Next winter, drain the backflow preventer completely using test cocks and ball valves. Leave test cocks open 45°. Insulate with a backflow blanket or enclosure. Freeze damage is 100% preventable.
Don't buy a new unit—rebuild the poppet and winterize properly going forward.