1. Home
  2. Question and Answer
  3. Houseplants
  4. Garden Articles
  5. Most Popular Plants
  6. Plant Nutrition

New Manifold Installed: Heads Don't Pop Up, Stay On Until Main Off

If all heads run but don't pop up after new manifold install — valves are stuck open hydraulically.

Check

  • All valves in closed position?
  • Bleeder screws snug?
  • Diaphragms clean, no debris?

Issue is hydraulic — focus on valve internals, not controller.