The system has a Hardie valve downstream of the pump with two handles on the stem, a small sensing line to the pump inlet, and no solenoid. The well has strong artesian pressure. The owner wants to know if this valve can be eliminated when replacing a leaking indexing valve.
This is a hydraulic valve - the predecessor to modern electric solenoid valves. Hydraulic systems used water pressure through small control tubes to actuate valves, managed by a hydraulic controller (not an electric timer). The sensing line to the pump inlet suggests it may function as a pressure-regulating or pump-protection device.
Not without major system changes. If you disconnect this hydraulic valve, you must replace it with a standard 24VAC electric solenoid valve AND install a modern electric controller. The existing hydraulic controller cannot operate electric valves.
Since you're already replacing the indexing valve, consider upgrading the entire system to modern electric valves with a standard controller. This eliminates the complex hydraulic tubing, provides more reliable operation, and allows use of contemporary smart controllers with weather-based scheduling.
If you must keep the hydraulic system, source a replacement hydraulic valve from specialty irrigation suppliers who service older agricultural systems.
Sprinkler System Won't Shut Off: Valve vs. Controller Diagnosis
Hardie HD-6100 Valve Replacement: Rebuild vs. Replace
Hardie Valve Parts in Spring/Houston: Try Ewing or Sprinkler World
Replacing Obsolete Rain Jet Valves: Compatible Options
Hardie 1.5" Valve Slow Leak – Diaphragm or Cracked Body
Hardie Total Control "Short" Error – Controller or Solenoid #6
Identifying Vintage Brass Hydraulic Valves: The Imperial Brand
Two Zones Dead After Wire Repair? Check Valve Voltage & Water Supply
Leaking Sprinkler Heads: Valve Diaphragm or Low-Head Drainage?
Irrigation Pump Runs But No Water at Valves—Master Valve or Pump Relay
Sourcing Hardie Valve Diaphragms in Sacramento: Replace Diaphragm and Solenoid Together
Hardie 11-Year System: Zone 1 Failed Progressively, Now Dead
Hardie RD600: Valve Wiring and Manual Operation
All Six Toro Valves Stuck Open After Winter: Pressure and Sequence Fix
Copyright © www.100flowers.win Botanic Garden All Rights Reserved