An ESP-8 controller's fuse blows immediately when the system attempts to start, but the pump runs fine when the main valve (Rain Bird 100-DV) is operated manually. The issue is isolated to the master valve circuit.
If the solenoid tests good, inspect the wires between the controller and the valve for nicks, shorts, or waterlogged connections. Repair or replace damaged sections.
Replace the solenoid (or the entire valve top if the dump port is clogged). The 100-DV's solenoid unscrews easily; ensure the new one is the same voltage (24 VAC).