A blank LCD on a Hardie RD-1200 (or Rain Dial RD-1200) with confirmed 24 VAC at the controller terminals usually points to an internal failure. Unlike later Irritrol-branded RD-1200s, the original Hardie boards often lack a replaceable fuse.
This clears microprocessor latch-up caused by power surges or brownouts.
Use a multimeter to confirm 24–28 VAC at the controller's power input terminals. If voltage is low or absent, replace the transformer (any 24 VAC, 40 VA unit works).
If the reset doesn't restore the display, budget for a new controller. It's the most reliable long-term fix.