1. Home
  2. Question and Answer
  3. Houseplants
  4. Garden Articles
  5. Most Popular Plants
  6. Plant Nutrition

Toro Greenkeeper 212 Water Drop Symbol: Rain Sensor or Controller Fault

Toro Greenkeeper 212 shows water drop with slash (rain sensor active) and won't run. Two likely causes.

1. Rain Sensor Active/Wired Wrong

  • Check sensor: dry? Clean? Wired to SEN terminals?
  • Jumper SEN terminals at controller → if runs, sensor/wiring issue.

2. Controller Output Failed

  • Test: run station 1 manually, measure 24VAC at terminal 1 vs C.
  • No voltage → controller dead. Replace.
  • Voltage OK → valve/solenoid fault.

Quick Path

Jumper sensor terminals first. If it runs, disable sensor in menu or fix wiring. If not, test controller output.

Greenkeeper 212 is old—replacement (Toro Evolution, Hunter X-Core) is better than repair.