Toro Greenkeeper 212 Switch Failure: 'Power Off' Display and Uncommanded Operation

"Power Off" Symbol On; Power Actually On; Battery Changed; Ran in Rain Delay, Then Off, Then Restarted Next Day

The mode switch contacts are worn—the controller doesn’t recognize the OFF position. The microprocessor is likely failing.

Replace with an Irritrol Rain Dial or Rain Bird ESP controller.