"PR OFF" on a Rain Bird ESP-6TM means no 110VAC power to the controller or a blown internal fuse. If valves still operate manually, the controller panel is failing.
Some ESP models have a small glass fuse on the circuit board (0.5A, 250V). Replace if blown. If no fuse or replacement doesn't fix, the controller board has failed.
"PR" = "Power". The display is telling you the controller isn't seeing line voltage. If the system waters but shows this, the panel is glitching—plan replacement.