Rain Bird ESP-4 LCD Display Garbled—Panel Replacement

6-year-old ESP-4 works but LCD shows all characters at once (unreadable). Can display be replaced separately?

Reset Attempt

  1. Remove battery
  2. Disconnect power 1 minute
  3. Power on WITHOUT battery
  4. Check display

If Still Garbled

Faceplate/panel replacement available — cheaper than full cabinet. Order ESP-4 faceplate. DIY install: disconnect ribbon cable, swap panel, reconnect.