An old Hardie HR6100 (marked IR05) runs zone 1 continuously in auto mode but shuts off manually. The homeowner wonders if controller replacement is needed.
Since manual operation works, the valve mechanism functions. If the valve closes when controller loses power, the controller's output transistor for that station is likely shorted closed. Given the unit's age (Hardie became Irritrol decades ago), replacement with a modern Irritrol Rain Dial is the practical solution.