New homeowners inherited a Hunter SRC Plus 6-zone system where 2 zones failed during inspection. One zone worked briefly (4 minutes of 15) then stopped; the other never operated from controller but worked manually at the valve. This indicates electrical issues rather than hydraulic problems.
Since manual valve operation works, the valves and hydraulics are functional. The problem lies in the electrical path: controller output, field wiring, or solenoid coils. Required tools: multimeter (volt/ohm).
If comfortable with electrical testing, proceed systematically. Otherwise, consult an irrigation professional. The intermittent operation of one zone suggests a marginal connection or failing solenoid.