A homeowner with a Nelson 8300 controller found four unmarked black valves in the valve box. One zone runs continuously unless the controller is unplugged, and another has low pressure. The goal: rebuild all four valves with original parts.
The valves are Nelson model 9001 or 9002. Both share the same diaphragm and solenoid; the difference is pipe connection (glue-in vs. threaded). Look for markings on the top or sides of the valve body.
Since zones function except for the two issues, rebuilding all valves proactively prevents future failures. The constant-on zone likely has a stuck solenoid plunger or debris preventing diaphragm seating. Low pressure may indicate a torn diaphragm or clogged solenoid port.