Water pressure ~65 PSI, 1" line to 1" valve, ~10 GPM flow. Wants Hunter I-40 with 1" inlet. Asks for formula to calculate heads per valve.
Matt: "If you look at a hunter I-40 nozzle chart the lowest one will operate is about 10 GPM. Your valve will flow 25-30 GPM, but your 1" pipe is going to max out about 15-18 GPM. (You can push more through 1", but the pressure drop increases drastically.) So the most you can run is 1 head per valve."
With 4 GPM nozzles you could run 4 heads on 1" line. "In this case your pipe is the limiting factor."