Water hammer and leakage at the backflow preventer's relief port usually indicate excessive flow velocity caused by a supply line larger than the valve inlet or downstream piping. The sudden pressure changes make pipes rattle and force the backflow's poppet open, dumping water.
Ensure the backflow device is the correct type for your hazard level and installed at least 12″ above the highest head. A leaking relief port during operation often means the device is doing its job—preventing backflow—but the system pressure is too high or fluctuating violently.