The controller displays "FUSE" on every zone attempt. The unit is 10+ years old.
A short circuit detected on the station output: either a bad solenoid or a shorted field wire.
Since all zones show the error simultaneously, it's unlikely all solenoids failed at once. The controller's circuit board or a common wiring fault (e.g., severed common wire touching hot) is more probable. Given the controller's age, replacement is recommended.