21-year-old Richdel 445 with 2 new brass valves (9 heads each, 3/4" line). One zone low pressure from controller, but good pressure when manually bled at valve.
New valves rule out diaphragm. Good manual pressure rules out supply line. Controller activates solenoid but valve doesn't open fully. Solenoid bleed port (tiny hole in solenoid chamber) likely clogged with debris.
Debris from supply line or new installation lodges in critical solenoid vent port. Valve needs this port to vent upper chamber for full opening. Manual bleed bypasses this port.