Hydro Rain Blows Fuse Only in Auto on Zone 4: Transition or Wiring Issue

Strange Behavior: Fuse Blows in Auto Mode Zone 3→4 Transition, Not in Manual

Suggests an issue during the automatic handoff from Zone 3 to Zone 4.

Isolation Procedure

  1. Disconnect field wire from controller terminal #4. Run auto. - Still blows → disconnect terminal #3 wire, run auto. - Still blows → controller internal fault. - No blow → fault in Zone 3 wire or solenoid. - No blow with #4 disconnected → fault in Zone 4 wire or solenoid.

Why This Works

Removing the load (solenoid) from the circuit isolates whether the short is in the controller's output stage or the field circuit.