Manual cycle test: zones 1, 2, 4, 5. Zone 4 kept running even when switching back to zone 1 or turning controller off. Only stopped by closing the main water valve.
A sticking diaphragm or obstructed exhaust port prevents the valve from closing when the solenoid de-energizes.