Manual start: hear water draining from solenoids, no pressure, one head seeps.
"Water draining" is likely solenoid buzz (normal). To test pressure: shut off main, unscrew a solenoid, turn main on. Stream from solenoid port = pressure OK, diaphragm bad. No stream = mainline blockage. Seeping head: if slight top seep, diaphragm bad. If heavy base leak, cracked nipple under head—replace nipple.
Troubleshooting a Sprinkler Zone That Shows Active but Delivers No Water
Water Running Sound at One Valve When System Off – Valve Not Sealing
Well Pump Blows Pressure Relief Valve When Zone Activates
Rain Bird ESP-LX "Fault 4" Code: Zone Skipped
Water Hammer Zones 2 & 3: Reduce Heads or Move Backflow to Main
Resolving Chronic Yard Drainage and Property Assessment Issues
Low Pressure on One Sprinkler Zone: Valve Adjustment and Cleaning
Fixing a Sprinkler Valve That Won't Shut Off: Diaphragm Replacement
Sprinkler Solenoid Testing After Controller Voltage Confirmed—Ohmmeter Method
Choosing a Sprinkler Valve for Low-Pressure Tank Drainage
One Zone Lost Pressure: Hardie Valve Diaphragm Likely Culprit
Sprinkler Water Unsuitable for In-Ground Bog Gardens
Indoor Miniature Rose: Brown Leaf Tips from Overwatering and Lack of Dormancy