Hardie 9-Station Controller Repeats Watering Cycle: Disable Extra Start Times

All Zones Run at Correct Times but Cycle Repeats; Must Manually Turn Off

Extra start times are active.

  1. Go to Start Time 2 → set to OFF.
  2. Go to Start Time 3 → set to OFF.
  3. Keep only Start Time 1 active.

Manual at irritrol.com under "Rain‑Dial".